HOME   |    CONTACT US   |    DETAILED EXPERIENCE   | PROJECTS INDEX  
Bray Solutions Pty Limited
Year
Service
Features of Plant
Inlet Flow & Pressure
Role in Project

1994
In-seam
*Fixed plant
*Three liquid-ring vacuum pumps *280kW electric motors/VVVF drives
*Automatic flow control by variable speed
*Acoustic enclosure on motors
8,000 actual litre/s

-50 kPa gauge
*Devised process concept,
*Sized and specified equipment and pipes, *Wrote Functional Specification,
*Led design team,
*Supervised commissioning,
*Conducted training



1996
Goaf
*Portable plant (three built)
*Centrifugal fan
*Electric motor/VVVF drive
*Automatic flow control by variable speed
*Acoustic enclosure on assembled unit.
2,000 actual litre/s each

-12 kPa gauge
*Devised process concept,
*Sized and specified equipment,
*Wrote Functional Specification,
*Led design team,
*Supervised commissioning,
*Conducted training



Dartbrook Coal Gas Plants